Avoid Long Delays in Instrument Decontamination, Reprocessing

Leaving instruments unprocessed for any period of time can lead to the development of biofilm. The recommendation is to begin the cleaning process as soon as possible. As a matter of fact, a number of manufacturer’s instructions for use (IFUs) are now specifying the time frame that cleaning should be implemented. This ranges from “immediately after use” to “within 10, 20 sau 30 minute;” it varies with the device/instrument manufacturer. The manufacturer’s IFUs should always be followed.

APP: Punctul de #73

As President of the Association of Professional Piercers, I have a regular editorial column in The Point magazine. Litigiu 73 editorial Please enjoy

APP Conference soon!

  CONFERENCE IS ALMOST UPON US! THE CONFERENCE ADVANCED (ONLINE) REGISTRATION WILL SHUT DOWN AT MIDNIGHT ON MAY 17TH, PST ANY CHANGES TO YOUR REGISTRATION SHOULD

Obţine o STATIM 2000 G4

FDA de orientare pe Sterilizatoare

Autoclave ce sunt aprobate pentru a steriliza elemente tubulare de FDA?
Standardele pentru Autoclave care pot procesa elemente cu lumeni sunt accesibile publicului prin intermediul site-ul FDA.

Effects of Non-Condensable Gases (NCGs) on Steam Sterilisation Processes

A study conducted by Prof. von Eiff of University of Münster in hospitals in North Rhine Westphalia and Lower Saxony revealed that, in particular, 40% of hollow instruments released for use were not sterile (4). One reason for such problems is that the classic biological and/or well-integrated chemical indicators can attest to the sterility of supplies only at those locations at which they are positioned. But in general these indicators cannot be placed at those sites within the instrument which are most difficult to access, hence the established practice of using such indicators is not suitable for providing insights into the sterility of lumened devices.

Curajos

Welcome to Bravo! A fractionated vacuum autoclave from SciCan Buy a Bravo now BRAVO chamber autoclave Features Fractionated vacuum

Revenirea culturi la pacienţii

În curs de dezvoltare o politica de a reveni de culturi la pacienţii [sau bijuterii purtate anterior clientilor] Există multe preocupările şi problemele pe care trebuie să fie luate în considerare şi adresat.

Sharpies pentru etichetarea

“Majoritatea Sharpies nu au fost validate pentru utilizare industrială sau pentru utilizarea în condiţii de sterilizare. Există o serie de markeri Sharpie conforme cu ASTM D4236 standard, ceea ce înseamnă produsul a fost evaluat de un toxicolog pentru toxicitatea acută şi cronică şi fişa tehnică privind siguranţa (SDS) identifică ingrediente ca prezentând orice pericol de sănătate cronice, împreună cu instrucţiunile de utilizare în condiţii de siguranţă. Pixuri care poartă sigiliul AP cu notaţia “conform cu ASTM D4236″ (a se vedea dreapta) sunt markeri care pot fi utilizate pentru etichetarea pachetele dumneavoastră.”

Protocolul de 33TB OPTIM

Un protocol pentru trecerea la OPTIM 33 Dezinfectant TB cu un pas mai curat, şi un ghid rapid de referinţă pentru tatuaj şi Piercing